Ion Selective Electrodes

Ammonia ISE: Ammonia

An Ion Selective Electrode sensor specifically designed to measure Ammonia from 0.01 ppm to 17,000 ppm NH3 (5x10-7 M to 1M) concentrations.
Applications include, but not limited to: High Purity Power Station Water, Fish Tanks, Sea Water, Waste Water, Plating Baths, Biological Samples.

Ammonium ISE: Ammonium

An Ion Selective Electrode sensor specifically designed to measure 0.1ppm to 18,000 ppm (5x10-6M to 1M) concentrations of NH4.
Applications inclue, but not limited to: Boiler Feed Water, Natural Waters, Fertilizers.

Bromide ISE: Bromide

A Bromide Ion Selective Electrode sensor specifically designed to measure 0.4ppm to 79,900 ppm (5x10-6 M to 1M) concentrations of Bromide.
Applications include, but not limited to: Water, Wine, Soil and Plant Tissue, Blood Electrolytes/Clinical Analysis.

ISE: Cadmium

A Cadmium Ion Selective Electrode sensor specifically designed to measure 0.01 ppm to 11,200 ppm (10-7 M to 10-1 M) concentrations of Cd+2.
Applications include, but not limited to: Plating Baths.

ISE: Calcium

A Calcium Ion Selective Electrode sensor specifically designed to measure 0.2 ppm to 40,000 ppm (5x10-6 M to 1M) concentrations of Ca+2.
Applications include, but not limited to: Water Softening Systems, Drinking and Mineral Waters, Blood Elecrtrolytes/Clinical Analysis.

ISE: Carbon Dioxide

A Carbon Dioxide Ion Selective Electrode sensor specifically designed to measure 4.4 ppm to 440 ppm (10-4 M to 10-2 M) concentrations of CO2.
Applications include, but not limited to: Soft Drinks, Wine, Fermentation.

ISE: Chloride

A Chloride Ion Selective Electrode sensor specifically designed to measure 1.8 ppm to 35,500 ppm (5x10-5 M to 1M) concentrations of Cl-.
Appliations include, but not limited to: River and Tap Water, Plant Tisue, Soils, Boiler Feed Water, Blood Electrolytes/Clinical Analysis, Sweat, Urine, Cement, Plating Baths, Food Samples.

ISE: Copper

A Copper (Cupric) Ion Selective Electrode sensor specifically designed to measure 0.0006 ppm to 6350 ppm (10-8 M to 10-1 M) concentrations of Cu+2.
Applications include, but not limited to: Plating Baths, Water.

ISE: Cyanide

A Cyanide Ion Selective Electrode sensor specifically designed to measure 0.1 ppm to 260 ppm (5x10-6 M to 10-2 M) concentrations of CN-.
Applications include, but not lmited to: Plating Baths, Waste Water, Plant Tissue.

ISE: Fluoride

A Fluoride Ion Selective Electrode sensor specifically designed to measure .02 ppm to saturated (10-6 M to saturated) concentrations of F-.
Applications include, but not limited to: Drinking Water, Wastewater and Natural Waters, Air and Stack Gases, Acids, Sea Water, Minerals, Soil, Foods, Biological Fluids, Toothpaste.

ISE: Fluoroborate

A Fluoroborate Ion Selective Electrode sensor specifically designed to measure 0.1 ppm to 10,800 ppm (7x10-6 M to 1M) concentrations of BF4-.
Applications include, but not limited to: Plating Baths.

ISE: Iodide

An Iodide Ion Selective Electrode sensor specifically designed to measure 0.006 ppm to 127,000 ppm (5x10-8 M to 1M) concentrations of I-.
Applications include, but not limited to: Milk, Feeds andPlants, Pharmaceuticals.

ISE: Lead

A Lead Ion Selective Electrode sensor specifically designed to measure 0.2 ppm to 20,700 ppm (10-6 M to 0.1M) concentrations of Pb+2.
Applications include, but not limited to: Plating Baths.

ISE: Nitrate

A Nitrate Ion Selective Electrode sensor specifically designed to measure 0.5 ppm to 62,000 ppm (7x10-6 M to 1M) concentrations of NO3-.
Applications include, but not limited to: Surface Waters and Sewage Effluent, Drinking Waters and Soil Extracts, Fertilizers, Soils, Plant Tissue, Meat, Potatoes, Spinach, Beets, Baby Food.

ISE: Nitrogen Oxide

A Nitrogen Oxide Ion Selective Electrode sensor specifically designed to measure 0.2 ppm to 220 ppm (5x10-6 M to 5x10-3 M) concentrations of NOx.
Applications include, but not limited to: Air, Stack Gases.

ISE: Perchlorate

A Perchlorate Ion Selective Electrode sensor specifically designed to measure 0.7 ppm to 98,000 ppm (7x10-6 M to 1M) concentrations of ClO4-.
Applications include, but not limited to: Explosives, Solid Propellants.

ISE: Potassium

A Potassium Ion Selective Electrode sensor specifically designed to measure 0.04 ppm to 39,000 ppm (10-6 M to 1M) concentrations of K+.
Applications include, but not limited to: Waste Water, River and Tap Waters, Blood Electrolytes/Clinical Analysis, Saliva, Serum, Fertilizer, Soils, Wines.

ISE: Silver/Sulfide

A Silver / Sulfide Ion Selective Electrode sensor specifially designed to measure either 0.01 ppm to 107,900 ppm (10-7 M to 1M) concentrations of Silver (Ag+), or 0.003 ppm to 32,100 ppm (10-7 M to 1M) concentrations of Sulfide (S-2).
Applications include, but not limited to: Sewage effluent, Soils, Sediments (Sulfide), Plating Baths (Silver), Photographic Fixing Solution (Silver).

ISE: Sodium

A Sodium  Ion Selective Electrode sensor specifically designed to measure 0.02 ppm to 100,000 ppm (10-6 M to 5M) concentrations of Sodium (Na+).
Applications include, but not limited to: Steam Condensates in Power Plants, Blood Electrolytes/Clinical Analysis, Serum, Foods, Wine, Sea Water.

ISE: PPB Sodium

A Sodium Ion Selective Electrode sensor specifically designed to measure 0.1 ppb to 10 ppm concentrations of Sodium (Na+).  Application include, but not limited to: Power Plants, Boiler Feed Water.

ISE: Surfactant

A Surfactant Ion Selective Electrode sensor specifically designed to measure 1.0 ppm to 12,000 ppm (10-5 M to 10-2 M) concentrations of surfactants.
Applications include, but not limited to: Detergents, Dishwashing Liquids, Cleaning Supplies, Food Products.

ISE: Water Hardness

A Water Hardness Ion Selective Electrode sensor specifically designed to measure 0.4 ppm to 40,000 ppm (10-5 M to 1M) concentrations of Water Hardness (Calcium and Magnesium).
Applications include, but not limited to: Water Softening Systems, Drinking and Mineral Waters, Sea Water.

Steam Sterilizable Carbon Dioxide Electrode

The Van London - pHoenix Co. Steam Sterilizable Carbon Dioxide probe is specifically designed for fermentation applications where it is necessary to subject the electrode to repeated steam sterilizations.

 